Description
Model: Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex
Part Number: 376 FC
Ordering Number: 1C7459
The Fluke 376 FC is part of the Fluke Connect family of wireless test tools. Now you can:
- Log and trend measurements to pinpoint intermittent faults
- Transmit results wirelessly via Fluke Connect® Measurements app
- Create and send reports right from the field
- Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices
The Fluke 376 FC is the direct replacement for the Fluke 376 Clamp Meter.
Includes:
- 18-inch iFlex® Flexible Current Probe
- TPAK magnetic hanging strap
- Soft carrying case
- TL75 test leads
- Two AA Alkaline batteries
- Coated instruction card
- Safety information sheet
Features
- Connect your meter to your smartphone with Fluke Connect Measurements
- Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
- Record results directly to your phone and the Cloud
- Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
- Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
- iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)
- TPAK magnetic hanging strap (included)
- Integrated VFD low pass filter for accurate motor drive measurements
- Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- CAT IV 600 V, CAT III 1000 V safety rating
- Three-year warranty
- Soft carrying case
Measurement Capability
- 1000 A ac and dc current measurement
- 2500 A ac current measurement with iFlex flexible current probe
- 1000 V ac and dc voltage measurement
- True-rms voltage and current for accurate measurements on non-linear signals
- Frequency measurement to 500 Hz with body jaw and iFlex
- Resistance measurement to 60 kΩ with continuity detection
- Min, max, average, and inrush recording to capture variations automatically
- 500 mV dc measurement range to interface with other accessories
- 1000 μF capacitance measurement
General Specifications
AC Current via Jaw | ||
Range | 999.9 A | |
Resolution | 0.1 A | |
Accuracy | 2% ±5 digits (10 Hz to 100 Hz) | |
2.5% ±5 digits (100-500 Hz) | ||
Crest Factor (50 Hz/60 Hz) | 3 @ 500 A | |
2.5 @ 600 A | ||
Add 2% for C.F. >2 |
Flexible Current Probe
AC Current via Flexible Current Probe | ||
Range | 2500 A | |
Resolution | 0.1 A (≤ 600 A) | |
1 A (≤ 2500 A) | ||
Accuracy | 3% ±5 digits (5 – 500 Hz) | |
Crest Factor (50/60Hz) | 3.0 at 1100 A | |
2.5 at 1400 A | ||
1.42 at 2500 A | ||
Add 2% for C.F. > 2 |
Frequency via Flexible Current Probe | ||
Range | 5.0 Hz to 500.0 Hz | |
Resolution | 0.1 Hz | |
Accuracy | 0.5% ±5 digits | |
Trigger level | 5 Hz to 20 Hz, ≥25 A | |
20 Hz to 100 Hz, ≥20 A | ||
100 Hz to 500 Hz, ≥25 A |
Position Sensitivity
i2500-10 Flex | i2500-18 Flex | |
A | ||
Distance from Optimum | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) |
Error | ±0.5 % | ±0.5 % |
B | ||
Distance from Optimum | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) |
Error | ±1.0 % | ±1.0 % |
C | ||
Distance from Optimum | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) |
Error | ±2.0 % | ±2.0 % |
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. |
Specifications
DC Current | ||
Range | 600.0 A | |
Resolution | 0.1 A | |
Accuracy | 2% ±5 digits | |
AC Voltage | ||
Range | 1000 V | |
Resolution | 0.1 V (≤600.0 V) | |
1 V (≤1000 V) | ||
Accuracy | 1.5% ±5 digits (20 Hz to 500 Hz) | |
DC Voltage | ||
Range | 1000 V | |
Resolution | 0.1 V (≤600.0 V) | |
1 V (≤1000 V) | ||
Accuracy | 1% ±5 digits | |
mV dc | ||
Range | 500.0 mV | |
Resolution | 0.1 mV | |
Accuracy | 1% ±5 digits | |
Frequency via Jaw | ||
Range | 5.0 Hz to 500.0 Hz | |
Resolution | 0.1 Hz | |
Accuracy | 0.5% ±5 digits | |
Trigger level | 5 Hz to 10 Hz, ≥10 A | |
10 Hz to 100 Hz, ≥5 A | ||
100 Hz to 500 Hz, ≥10 A |
Resistance | ||
Range | 60 kΩ | |
Resolution | 0.1 Ω (≤600 Ω) | |
1 Ω (≤6000 Ω) | ||
10 Ω (≤60 kΩ) | ||
Accuracy | 1% ±5 digits | |
Capacitance | ||
Range | 1000 μF | |
Resolution | 0.1 μF (≤ 100 μF) | |
1 μ F (≤ 1000 μF) | ||
Accuracy | 1% ±4 digits |
Mechanical Specifications
Maximum voltage between any terminal and earth ground | 1000 V | |
Batteries | 2 AA, NEDA 15A, IEC LR6 | |
Operating temperature | -10 °C to +50 °C | |
Storage temperature | -40 °C to +60 °C | |
Operating humidity - non-condensing (< 10°C) |
≤90% RH (at 10 °C to 30 °C) | |
≤75% RH (at 30 °C to 40 °C) | ||
≤45% RH (at 40 °C to 50 °C) | ||
Operating altitude | 3000 m | |
Storage altitude | 12,000 m | |
Size (L x W x H) | 249 x 85 x 45 mm | |
Weight | 395 g | |
Jaw opening | 34 mm | |
Flexible current probe diameter | 7.5 mm | |
Flexible current probe cable length (head to electronics connector) |
1.8 m | |
Safety | IEC 61010-1, Pollution Degree 2 | |
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V | ||
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V | ||
IP rating | IEC 60529: IP30, non-operating | |
Radio Frequency Certification FCC ID | T68-FBLE IC:6627A-FBLE |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |