Description
| 4-Point Earth Resistance Measurement | |
| Range (Auto-Ranging) | 0.01Ω to 99.99kΩ |
| Resolution | 0.001 to 10Ω |
| Accuracy | ±(2% Reading +1ct) |
| Test Voltage | 16 or 32V; 41 to 513Hz |
| Test Current | Up to 250mA |
| Selective 4-Pole (with optional probes MN82 or SR182) | |
| Same characteristics as with 4-point earth resistance measurement | |
| 3-Point Earth Resistance Measurement | |
| Range (Auto-Ranging) | 0.09Ω to 99.9kΩ |
| Resolution | 0.01 to 100Ω |
| Accuracy | ±(2% Reading +1ct) |
| Test Voltage | 16 or 32V; 41 to 513Hz |
| Test Current | Up to 250mA |
| Soil Resistivity 4-Point Measurement | |
| Test method | Wenner or Schlumberger selectable with automatic calculation |
| Range (Auto-Ranging) | 0.01Ω to 99.9kΩ; ρ max: 999kΩm |
| Resolution | 0.01 to 100Ω |
| Accuracy (Typical) | ±(2% Reading +1ct) |
| Test Voltage | 16 or 32V; 41 to 128Hz selectable |
| 2 Clamp Ground Measurement (with optional probes MN82 or SR182) | |
| Range (Auto-Ranging) | 0.1 to 500Ω |
| Resolution | 0.01 to 1Ω |
| Measurement Frequency | Auto: 1611Hz; Manual: 128Hz-1367Hz-1611Hz-1758Hz |
| DC Resistance Measurement (Bond Testing) 2-Pole (with lead resistance compensation) or 4-Pole (Kelvin sensing) | |
| Range (Auto-Ranging) | 2-pole: 0.12Ω to 99.9kΩ 4-pole: 0.020Ω to 99.99kΩ |
| Resolution | 2 -pole: 0.01 to 100Ω 4-pole: 0.001 to 10Ω |
| Accuracy (Typical) | ±(2% Reading +2ct) |
| Test Voltage | 16V DC; (+, - or auto polarity) |
| Test Current | Up to 250mA |
| Current Measurement (with optional probes MN82 or SR182) | |
| Range | 0.01mA to 40A, 16 to 400Hz |
| Accuracy (Typical) | ±(3% Reading +2ct) typical |
| External Voltage Measurement | |
| Range | 0.1 to 65V AC/DC – DC, 15 to 440Hz |
| Accuracy | ±(2% Reading +1ct) |
| General Features | |
| Memory | 512 measurements (64KB) |
| Communication | USB 2.0 optically isolated, DataView software included |
| Power Source | 9.6V rechargeable battery pack with external 110/220V charger |
| Battery Life | 1500 tests typical in automatic mode |
| Dimensions | 10.7 x 9.80 x 5.12” (272 x 248 x 130mm) |
| Weight | 7lbs (3.2kg) with battery |
| Case | UL V0 Polypropylene |
| Operating Temperature | 32° to +113°F (0° to +45°C) |
| Storage Temperature | -40° to 158°F (-40° to +70°C) |
| Relative Humidity | Up to 90>#/td### |
| Ingress Protection (IP) | IP 53 with cover closed |
| EMC | EN 61326-1 |
| Safety Compliance | IEC 61010-1, EN 61557, 50V CAT IV, Pollution Degree 2 |
User Manuals
Modelo 6471 - Spanish (CA France version)
Model 6471 - French (CA France version)
Ground Resistance Calibration Checker
Datasheets
GroundFlex Field Kit - Models 6472 & 6474 - English
Brochures
Ground Resistance Testers Brochure
Comparison Charts
Ground Tester Comparison Chart - English
Tabla de Selección de Medidores de Tierra - Spanish
Software/Firmware
Application Notes
Battery Recharge Time / Rechargeable NiMH Notice
Tiempo de recarga de las baterías / Aviso de NiMH recargable
App-Touch-Step-Potential_Spanish
Megohmmeter Calibration Checker and Ground Resistance Checker
Workbooks
Understanding Ground Resistance - English
Understanding Ground Resistance - Spanish
Forms
Fall-of-Potential Report - PDF
Fall-of-Potential Report - Excel
Soil Resistivity Made Easy - PDF
Ground Testing Nomograph - PDF
Ground Testing Nomograph Example
Stored Measurement Results Form
Soil Resitivity Report - Excel
Single Rod Ground Resistance Calculation - Excel
Grounding Calculations and Charts - Excel
Calculators
Grounding Electrode Resistance Calculator

