FLIR DM285 IMAGING MULTIMETER WITH IGM™
Model: FLIR DM285 IMAGING MULTIMETER WITH IGM™
Part Number: DM285
Ordering Number:
The FLIR DM285 is a professional, all-in-one True RMS digital multimeter and thermal imager. Featuring Infrared Guided Measurement (IGM) technology powered by a built-in 160 x 120 FLIR thermal imager, the DM285 visually guides you to the precise location of an electrical problem without direct contact. You’ll pinpoint hot spots faster, safer, and more efficiently. The DM285 also helps streamline inspections by connecting wirelessly to FLIR Tools or the new FLIR InSiteTM workflow management app.
PINPOINT PROBLEMS QUICKLY AND SAFELY
- Find more work by visually identifying issues with IGM, and scan a panel or cabinet for hazards without direct contact.
SOLVE CHALLENGING PROBLEMS EASILY
- Performs 18 DMM measurement functions to help you verify the most complex electrical issues with trusted readings every time
STREAMLINED REPORTING AND SHARING
Features Bluetooth METERLiNK® to wirelessly embed data into thermal images from FLIR infrared cameras, or instantly share readings with clients.
- Auto Power Off
- Yes
- IR Resolution
- 19,200 pixels (160 x 120)
- Laser Pointer
- Yes
- Sensitivity
- ≤150 mK
- Size (L x W x H)
- 200 x 95 x 49 mm; Weight: 537 g
- Warranty
- 10 year
- Worklights
- Yes
Connectivity
- Bluetooth®
ENVIRONMENTAL
- Drop test
- 3m
- Emissivity Settings
- 4 Presets with Custom Adjustment
- IP Rating
- IP40
Display Size
- 2.8"
- Focus
- Fixed
- FOV (w x h)
- 46° x 35°
- Palette
- Iron, Rainbow, Greyscale
- Thermal Imaging Detector
- FLIR Lepton® microbolometer
Capacitance
- Range: 10.00 mF Basic Accuracy: ±1.9%
- Flex Clamp Range
- 3000 A AC (Optional TA72/74)
- Min/Max - Avg
- Yes
- Resistance
- Range: Basic Accuracy: 6.000 MΩ ±0.9% 50.00 MΩ ±3.0%
- Temperature Accuracy
- 3°C or 3.5%
- Temperature Range
- 14°F to 302°F (-10°C to 150°C)
- VFD
- Range: 1000 V Basic Accuracy: ±1.0%
- Continuity check
- 20 Ω and 200 Ω
- Measuring Rate
- 3 samples per second
- AC/DC LoZ V
- Range: 1000 V Basic Accuracy: ±1.5%
- AC/DC microAmps
- Range: 4,000 µA Basic Accuracy: ±1.0%
- AC/DC mVolt
- Range: 600 mV Basic Accuracy: 1% / 0.5%
- AC/DC Volts
- Range: 1000V Basic Accuracy: ±1.0% / 0.09%
- Battery
- 3 A A batteries; optional TA04 Li-Poly rechargeable battery
- AC/DC Amps
- Range: 10.00 A Basic Accuracy: ±1.5% / 1.0%
Data Logging & Storage
- 3 samples per second