{"title":"Current Transformers","description":"","products":[{"product_id":"peak-demand-cov-6-600v-current-transformers","title":"Peak Demand COV-6 (200:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COV-6 (200:5) Current Transformers \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOV0200SNN\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C9275\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 3.5” [89mm] x 4.5″ [114mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 6.00” [152mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMV-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAB-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCDW\/B\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan\u003eAll Peak Demand 600V metering CTs are now RUS listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COV-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.  The COV-6 is specifically engineered to fit on a 4” primary bus found in padmount transformers and can withstand temperatures to 85° C.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COV-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"No Baseplate","offer_id":40027611431109,"sku":"1C9275","price":338.76,"currency_code":"USD","in_stock":false},{"title":"Add Baseplate (+$15)","offer_id":40027611463877,"sku":null,"price":353.76,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COV-6_720px_d44c094b-2e25-44ff-b8c2-7b4102c78eb5.png?v=1528738596"},{"product_id":"peak-demand-col-6-600v-current-transformers-standard-accuracy","title":"Peak Demand COL0600SNN (600:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number: \u003c\/b\u003eCOL0600SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9247\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRatio: \u003c\/b\u003e600:5\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 5.5” [140mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 8.27” [210mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CLC-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAD-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCEW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes.  The COL-6 is specifically designed for higher ampere ratings with a large opening to handle primary cables.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COL-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":7493605064762,"sku":"1C9247","price":214.68,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COL-6_720px.png?v=1528737952"},{"product_id":"peak-demand-com-6-600v-current-transformers-standard-accuracy","title":"Peak Demand COM0100SNN (100:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COM0100SNN (100:5) Current Transformers\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOM0100SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9250\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 1200 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 2.6” [66mm]; 3.1″ [79mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 5.39” [137mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMF-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAK-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCCW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COM-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COM-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"No Baseplate","offer_id":40028006383813,"sku":"1C9250","price":138.08,"currency_code":"USD","in_stock":false},{"title":"Add Baseplate (+$15)","offer_id":40028006416581,"sku":"1C9250","price":153.08,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/b2f03993b6f7ff6241e6dc10fabaab345648c2ca_360px.png?v=1528738223"},{"product_id":"abb-200-5-ct","title":"200:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 200:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G01\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B6958\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":7833950519354,"sku":"1B6958","price":660.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/abb_cmv_360px.png?v=1528749710"},{"product_id":"peak-demand-col0800snn-800-5-current-transformers-standard-accuracy","title":"Peak Demand COL0800SNN (800:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number: \u003c\/b\u003eCOL0800SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9248\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRatio: \u003c\/b\u003e800:5\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 5.5” [140mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 8.27” [210mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CLC-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAD-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCEW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes.  The COL-6 is specifically designed for higher ampere ratings with a large opening to handle primary cables.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COL-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12711464665146,"sku":"1C9248","price":216.97,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COL-6_720px_e01a7685-8913-4cd5-a5e6-b4e8b90492fa.png?v=1528737978"},{"product_id":"peak-demand-col1000snn-1000-5-current-transformers","title":"Peak Demand COL1000SNN (1000:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number: \u003c\/b\u003eCOL1000SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9236\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRatio: \u003c\/b\u003e1000:5\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 5.5” [140mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 8.27” [210mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CLC-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAD-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCEW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes.  The COL-6 is specifically designed for higher ampere ratings with a large opening to handle primary cables.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COL-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12711657898042,"sku":"1C9236","price":206.78,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COL-6_720px_9885a080-7c54-432c-9b35-8981ea4024c1.png?v=1528738007"},{"product_id":"peak-demand-col1200snn-1200-5-current-transformers","title":"Peak Demand COL1200SNN (1200:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number: \u003c\/b\u003eCOL1200SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9237\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRatio: 12\u003c\/b\u003e00:5\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 5.5” [140mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 8.27” [210mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CLC-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAD-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCEW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes.  The COL-6 is specifically designed for higher ampere ratings with a large opening to handle primary cables.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COL-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12711783235642,"sku":"1C9237","price":209.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COL-6_720px_8e104b19-a9b3-4606-bb07-863fbd6ab6a8.png?v=1528738038"},{"product_id":"peak-demand-col1500snn-1500-5-current-transformers","title":"Peak Demand COL1500SNN (1500:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number: \u003c\/b\u003eCOL1500SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9239\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRatio: \u003c\/b\u003e1500:5\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 5.5” [140mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 8.27” [210mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CLC-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAD-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCEW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes.  The COL-6 is specifically designed for higher ampere ratings with a large opening to handle primary cables.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COL-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12711836516410,"sku":"1C9239","price":210.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COL-6_720px_be26a7dc-7c1c-47ba-bdfd-e7d8dc5c0325.png?v=1528738064"},{"product_id":"peak-demand-col2000snn-2000-5-current-transformers","title":"Peak Demand COL2000SNN (2000:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number: \u003c\/b\u003eCOL2000SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9241\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRatio: \u003c\/b\u003e2000:5\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 5.5” [140mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 8.27” [210mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CLC-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAD-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCEW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes.  The COL-6 is specifically designed for higher ampere ratings with a large opening to handle primary cables.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COL-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12711879540794,"sku":"1C9241","price":215.08,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COL-6_720px_ea6deebd-de8d-49d7-9069-dd709b7986ca.png?v=1528738085"},{"product_id":"peak-demand-col3000snn-3000-5-current-transformer","title":"Peak Demand COL3000SNN (3000:5) Current Transformer","description":"\u003cp\u003e\u003cb\u003eModel Number: \u003c\/b\u003eCOL3000SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9245\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRatio: \u003c\/b\u003e3000:5\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 5.5” [140mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 8.27” [210mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CLC-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAD-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCEW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes.  The COL-6 is specifically designed for higher ampere ratings with a large opening to handle primary cables.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COL-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12711919452218,"sku":"1C9245","price":218.63,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COL-6_720px_fdb2e86b-1783-4b40-82d9-e8ecfb134614.png?v=1528738115"},{"product_id":"peak-demand-col4000snn-4000-5-current-transformer","title":"Peak Demand COL4000SNN (4000:5) Current Transformer","description":"\u003cp\u003e\u003cb\u003eModel Number: \u003c\/b\u003eCOL4000SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9246\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRatio: \u003c\/b\u003e4000:5\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 5.5” [140mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 8.27” [210mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CLC-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAD-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCEW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes.  The COL-6 is specifically designed for higher ampere ratings with a large opening to handle primary cables.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COL-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12711957168186,"sku":"1C9246","price":228.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COL-6_720px_aab1f108-c6df-4249-80a9-212c2f5a2bb2.png?v=1528738160"},{"product_id":"peak-demand-cov-6-300-5-current-transformers","title":"Peak Demand COV-6 (300:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COV-6 (300:5) Current Transformers \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOV0300SNN\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C9303\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 3.5” [89mm] x 4.5″ [114mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 6.00” [152mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMV-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAB-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCDW\/B\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan\u003eAll Peak Demand 600V metering CTs are now RUS listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COV-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.  The COV-6 is specifically engineered to fit on a 4” primary bus found in padmount transformers and can withstand temperatures to 85° C.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COV-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12712974090298,"sku":"1C9303","price":307.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COV-6_720px_da63bced-f49c-422a-adfe-a6c47f442305.png?v=1528738659"},{"product_id":"peak-demand-cov-6-400-5-current-transformers","title":"Peak Demand COV-6 (400:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COV-6 (400:5) Current Transformers \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOV0400SNN\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C9278\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 3.5” [89mm] x 4.5″ [114mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 6.00” [152mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMV-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAB-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCDW\/B\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan\u003eAll Peak Demand 600V metering CTs are now RUS listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COV-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.  The COV-6 is specifically engineered to fit on a 4” primary bus found in padmount transformers and can withstand temperatures to 85° C.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COV-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713005973562,"sku":"1C9278","price":375.83,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COV-6_720px_9dead45b-795c-4f0f-8b40-e599e393cbb6.png?v=1528738789"},{"product_id":"peak-demand-cov-6-600-5-current-transformers","title":"Peak Demand COV-6 (600:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COV-6 (600:5) Current Transformers \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOV0600SNN\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C9280\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 3.5” [89mm] x 4.5″ [114mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 6.00” [152mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMV-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAB-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCDW\/B\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan\u003eAll Peak Demand 600V metering CTs are now RUS listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COV-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.  The COV-6 is specifically engineered to fit on a 4” primary bus found in padmount transformers and can withstand temperatures to 85° C.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COV-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713077145658,"sku":"1C9280","price":371.32,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COV-6_720px_e21af127-aeed-42a1-870d-e0c4223d0e23.png?v=1528738812"},{"product_id":"peak-demand-cov-6-800-5-current-transformers","title":"Peak Demand COV-6 (800:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COV-6 (800:5) Current Transformers \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOV0800SNN\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C9282\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 3.5” [89mm] x 4.5″ [114mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 6.00” [152mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMV-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAB-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCDW\/B\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan\u003eAll Peak Demand 600V metering CTs are now RUS listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COV-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.  The COV-6 is specifically engineered to fit on a 4” primary bus found in padmount transformers and can withstand temperatures to 85° C.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COV-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713109979194,"sku":"1C9282","price":335.17,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COV-6_720px_fc1acbf8-53ea-413c-9bee-a5c55ec147cb.png?v=1528738838"},{"product_id":"peak-demand-cov-6-1000-5-current-transformers","title":"Peak Demand COV-6 (1000:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COV-6 (1000:5) Current Transformers \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOV1000SNN\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C9315\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 3.5” [89mm] x 4.5″ [114mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 6.00” [152mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMV-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAB-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCDW\/B\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan\u003eAll Peak Demand 600V metering CTs are now RUS listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COV-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.  The COV-6 is specifically engineered to fit on a 4” primary bus found in padmount transformers and can withstand temperatures to 85° C.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COV-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713152970810,"sku":"1C9315","price":328.31,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COV-6_720px.png?v=1528738471"},{"product_id":"peak-demand-cov-6-1200-5-current-transformers","title":"Peak Demand COV-6 (1200:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COV-6 (1200:5) Current Transformers \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOV1200SNN\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C9273\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 3.5” [89mm] x 4.5″ [114mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 6.00” [152mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMV-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAB-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCDW\/B\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan\u003eAll Peak Demand 600V metering CTs are now RUS listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COV-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.  The COV-6 is specifically engineered to fit on a 4” primary bus found in padmount transformers and can withstand temperatures to 85° C.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COV-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713254682682,"sku":"1C9273","price":317.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COV-6_720px_c44e8129-022e-4a4d-ac41-5a42a57dc931.png?v=1528738504"},{"product_id":"peak-demand-cov-6-1500-5-current-transformers","title":"Peak Demand COV-6 (1500:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COV-6 (1500:5) Current Transformers \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOV1500SNN\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C9274\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 3.5” [89mm] x 4.5″ [114mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 6.00” [152mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMV-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAB-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCDW\/B\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan\u003eAll Peak Demand 600V metering CTs are now RUS listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COV-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.  The COV-6 is specifically engineered to fit on a 4” primary bus found in padmount transformers and can withstand temperatures to 85° C.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COV-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713286271034,"sku":"1C9274","price":321.38,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COV-6_720px_3fdc7a53-20cc-41f6-bc96-9e72a3dcd5e2.png?v=1528738528"},{"product_id":"peak-demand-cov-6-2000-5-current-transformers","title":"Peak Demand COV-6 (2000:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COV-6 (2000:5) Current Transformers \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOV2000SNN\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C9277\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 3.5” [89mm] x 4.5″ [114mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 6.00” [152mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMV-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAB-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCDW\/B\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan\u003eAll Peak Demand 600V metering CTs are now RUS listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COV-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.  The COV-6 is specifically engineered to fit on a 4” primary bus found in padmount transformers and can withstand temperatures to 85° C.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COV-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713352233018,"sku":"1C9277","price":355.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COV-6_720px_a2eb6bb9-a4dd-4246-9a42-f900d0efbec8.png?v=1528738568"},{"product_id":"peak-demand-cov-6-3000-5-current-transformers","title":"Peak Demand COV-6 (3000:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COV-6 (3000:5) Current Transformers \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOV3000SNN\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C9860\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 3.5” [89mm] x 4.5″ [114mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 6.00” [152mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMV-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAB-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCDW\/B\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan\u003eAll Peak Demand 600V metering CTs are now RUS listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COV-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.  The COV-6 is specifically engineered to fit on a 4” primary bus found in padmount transformers and can withstand temperatures to 85° C.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COV-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713387229242,"sku":"1C9860","price":412.28,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COV-6_720px_6e4bfcc9-835e-4eaf-a0e4-8545d277ba6e.png?v=1528738635"},{"product_id":"peak-demand-cov-6-4000-5-current-transformers","title":"Peak Demand COV-6 (4000:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COV-6 (4000:5) Current Transformers \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOV4000SNN\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C9279\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 3.5” [89mm] x 4.5″ [114mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 6.00” [152mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMV-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAB-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCDW\/B\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan\u003eAll Peak Demand 600V metering CTs are now RUS listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COV-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.  The COV-6 is specifically engineered to fit on a 4” primary bus found in padmount transformers and can withstand temperatures to 85° C.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COV-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713410068538,"sku":"1C9279","price":364.83,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/COV-6_720px_ae48d7ee-f398-4a3d-8a86-292c6cc2d00b.png?v=1528738765"},{"product_id":"peak-demand-com0200snn-200-5-current-transformers","title":"Peak Demand COM0200SNN (200:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COM0200SNN (200:5) Current Transformers\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOM0200SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9258\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 1200 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 2.6” [66mm]; 3.1″ [79mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 5.39” [137mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMF-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAK-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCCW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COM-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COM-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713550151738,"sku":"1C9258","price":142.03,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/b2f03993b6f7ff6241e6dc10fabaab345648c2ca_360px_fa29ed47-e820-4d56-b0cc-092065a25630.png?v=1528738252"},{"product_id":"peak-demand-com0400snn-400-5-current-transformers","title":"Peak Demand COM0400SNN (400:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COM0400SNN (400:5) Current Transformers\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOM0400SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9260\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 1200 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 2.6” [66mm]; 3.1″ [79mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 5.39” [137mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMF-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAK-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCCW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COM-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COM-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713568305210,"sku":"1C9260","price":128.2,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/b2f03993b6f7ff6241e6dc10fabaab345648c2ca_360px_b3513098-4b27-44b7-bf30-aad32aa98f9e.png?v=1528738281"},{"product_id":"peak-demand-com0500snn-500-5-current-transformers","title":"Peak Demand COM0500SNN (500:5) Current Transformers","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COM0500SNN (500:5) Current Transformers\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOM0500SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9264\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 1200 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 2.6” [66mm]; 3.1″ [79mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 5.39” [137mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMF-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAK-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCCW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COM-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COM-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713593733178,"sku":"1C9264","price":132.15,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/b2f03993b6f7ff6241e6dc10fabaab345648c2ca_360px_b1405932-a6d3-4133-9298-38734b4e0aed.png?v=1528738316"},{"product_id":"peak-demand-com0600snn-600-5-current-transformer","title":"Peak Demand COM0600SNN (600:5) Current Transformer","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COM0600SNN (600:5) Current Transformers\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOM0600SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9268\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 1200 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 2.6” [66mm]; 3.1″ [79mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 5.39” [137mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMF-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAK-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCCW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COM-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COM-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713805938746,"sku":"1C9268","price":134.13,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/b2f03993b6f7ff6241e6dc10fabaab345648c2ca_360px_aad85d91-260f-4d57-ace5-a658a52585f7.png?v=1528738342"},{"product_id":"peak-demand-com0800snn-800-5-current-transformer","title":"Peak Demand COM0800SNN (800:5) Current Transformer","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COM0800SNN (800:5) Current Transformer\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOM0800SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9270\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 1200 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 2.6” [66mm]; 3.1″ [79mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 5.39” [137mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMF-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAK-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCCW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COM-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COM-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713845194810,"sku":"1C9270","price":142.03,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/b2f03993b6f7ff6241e6dc10fabaab345648c2ca_360px_20488008-0655-4f58-9b3b-1d9bfbda39dc.png?v=1528738371"},{"product_id":"peak-demand-com1000snn-1000-5-current-transformer","title":"Peak Demand COM1000SNN (1000:5) Current Transformer","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COM1000SNN (1000:5) Current Transformer\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOM1000SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9254\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 1200 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 2.6” [66mm]; 3.1″ [79mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 5.39” [137mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMF-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAK-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCCW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COM-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COM-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713864921146,"sku":"1C9254","price":132.15,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/b2f03993b6f7ff6241e6dc10fabaab345648c2ca_360px_7a238296-25b5-455c-9c30-7b06799a9e41.png?v=1528738395"},{"product_id":"peak-demand-com1200snn-1200-5-current-transformer","title":"Peak Demand COM1200SNN (1200:5) Current Transformer","description":"\u003cp\u003e\u003cb\u003eModel Number:\u003c\/b\u003e Peak Demand COM1200SNN (1200:5) Current Transformer\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number: \u003c\/b\u003eCOM1200SNN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrdering Number: \u003c\/b\u003e1C9256\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 1200 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 2.6” [66mm]; 3.1″ [79mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 5.39” [137mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class:\u003c\/strong\u003e 0.15% from 1% of nominal current through Rating Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3% Standard Accuracy, No Baseplate, No Bar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eCross Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eABB AccuRange™ CMF-S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eGE ITI RevenueSense™ JAK-0S\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eRitz DCCW\/B\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003e600V Metering current transformers are used in a wide variety of commercial and industrial applications where revenue class metering is necessary for billing purposes. The COM-6 is specifically engineered for pole-mounted applications and wall-mounted meter cabinets.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p1\"\u003eThe core is constructed from wound layers of high accuracy, low loss electrical grade steel. The core is evenly wound with enamel coated copper wire to ensure against potential short circuits. The core and coil assembly is encapsulated in polyurethane specifically engineered for premium dielectric, mechanical and thermal properties for use in both indoor and outdoor applications.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp class=\"p2\"\u003eEach COM-6 has a unique serial number which allows the customer to track each test record. Certified test reports are stored electronically and provided with every shipment.\u003c\/p\u003e","brand":"Peak Demand","offers":[{"title":"Default Title","offer_id":12713898278970,"sku":"1C9256","price":134.13,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/b2f03993b6f7ff6241e6dc10fabaab345648c2ca_360px_b4de4dd0-c5eb-494c-855d-629588febc23.png?v=1528738432"},{"product_id":"abb-300-5-ct","title":"300:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 300:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G02\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B6959\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":13459686785082,"sku":"1B6959","price":660.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/abb_cmv_360px_ad3dc6fd-5bc5-41e2-806c-1fac385088b8.png?v=1528815052"},{"product_id":"abb-400-5-ct","title":"400:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 400:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G03\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B6960\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":13459712737338,"sku":"1B6960","price":660.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/abb_cmv_360px_6e914d4d-ad42-4d7f-a69d-64806a9865fd.png?v=1528815091"},{"product_id":"abb-600-5-ct","title":"600:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 600:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G04\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B6961\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":13459818741818,"sku":"1B6961","price":660.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/abb_cmv_360px_23f84c81-f30c-4aea-a990-683f161e1a48.png?v=1528815258"},{"product_id":"abb-800-5-ct","title":"800:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 800:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G05\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B6962\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":13459882639418,"sku":"1B6962","price":660.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/abb_cmv_360px_080bdc29-8b70-4639-adec-02c075426b87.png?v=1528815345"},{"product_id":"abb-1000-5-ct","title":"1000:5 CMV Current Transformer | ABB","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 1000:5 CMV Current Transformers\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G06\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B6963\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":13459911868474,"sku":"1B6963","price":660.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/abb_cmv_360px_b054b705-65b8-40cd-b5aa-6054fe5ee031.png?v=1528815390"},{"product_id":"abb-1200-5-ct","title":"1200:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 1200:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G07\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B6964\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":13459929006138,"sku":"1B6964","price":660.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/abb_cmv_360px_b5851c16-dd3b-4b38-a32f-6d1b41b0b513.png?v=1528815420"},{"product_id":"abb-1500-5-ct","title":"1500:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 1500:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G08\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B6965\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":13459955449914,"sku":"1B6965","price":741.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/abb_cmv_360px_9e10d75e-4914-4c0e-85f8-c287b76293ba.png?v=1528815463"},{"product_id":"abb-2000-5-ct","title":"2000:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 2000:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G09\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B6966\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":13460087898170,"sku":"1B6966","price":768.57,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/abb_cmv_360px_3cb6e991-d168-4af9-83c1-a833ee568935.png?v=1528815606"},{"product_id":"abb-3000-5-ct","title":"3000:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 3000:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G10\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B6967\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":13460122107962,"sku":"1B6967","price":782.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/abb_cmv_360px_ffce3362-0dc6-414d-84a7-c0bdbda9c40e.png?v=1528815649"},{"product_id":"abb-4000-5-ct","title":"4000:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 4000:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G11\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B6968\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":13460144554042,"sku":"1B6968","price":809.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/abb_cmv_360px_d3361aa9-ddcc-4235-ac0f-5f1299b27090.png?v=1528815694"},{"product_id":"abb-500-5-ct","title":"500:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 500:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G12\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B6969\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":13460167000122,"sku":"1B6969","price":660.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/abb_cmv_360px_0cf75635-3696-4996-b6f7-f51d72683602.png?v=1528815729"},{"product_id":"bl4-100-5-ct","title":"100:5 Split-Core Current Transformer | BL-4-100-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-4-100-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C7026\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 100A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-4 Series provides precision measurement for sub-metering,\u003cbr\u003econtrols and energy management without dismantling\u003cbr\u003ethe main line. Ergonomically designed with secured latch and\u003cbr\u003ekeying hole for locking or servicing tag.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.3” x 1.7” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5\u003cbr\u003e• Approximate weight 1.1Lbs\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Byram Labs","offers":[{"title":"Default Title","offer_id":16655818784826,"sku":"1B7026","price":120.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/bl_4.png?v=1533131742"},{"product_id":"bl2-150-5-ct","title":"150:5 Split-Core Current Transformer | BL-2-150-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-2-150-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C5893\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 150A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-2 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.0” x 1.4” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 0.5Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Byram Labs","offers":[{"title":"Default Title","offer_id":16656126574650,"sku":"1C5893","price":37.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/bl-2.png?v=1533131534"},{"product_id":"bl2-300-5-ct","title":"300:5 Split-Core Current Transformer | BL-2-300-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-2-300-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C5830\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 300A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-2 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.0” x 1.4” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 0.5Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Byram Labs","offers":[{"title":"Default Title","offer_id":16658664620090,"sku":"1C5830","price":43.33,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/bl-2_e6d21812-43f9-4f21-bcf1-dcf3f6f15c61.png?v=1533131589"},{"product_id":"bl2-400-5-ct","title":"400:5 Split-Core Current Transformer | BL-2-400-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-2-400-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C5857\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 400A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-2 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.0” x 1.4” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 0.5Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Byram Labs","offers":[{"title":"Default Title","offer_id":16659036143674,"sku":"1C5857","price":37.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/bl-2_0e6c5e66-74c0-49bf-98d2-b7deb6d59258.png?v=1533131611"},{"product_id":"bl4-200-5-ct","title":"200:5 Split-Core Current Transformer | BL-4-200-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-4-200-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C7027\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 200A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-4 Series provides precision measurement for sub-metering,\u003cbr\u003econtrols and energy management without dismantling\u003cbr\u003ethe main line. Ergonomically designed with secured latch and\u003cbr\u003ekeying hole for locking or servicing tag.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.3” x 1.7” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5\u003cbr\u003e• Approximate weight 1.1Lbs\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Byram Labs","offers":[{"title":"Default Title","offer_id":16659902726202,"sku":"1B7027","price":120.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/bl_4_3ba6f128-8374-4d48-ae45-be820bcfdb47.png?v=1533131785"},{"product_id":"bl4-300-5-ct","title":"300:5 Split-Core Current Transformer | BL-4-300-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-4-300-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C1391\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 300A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-4 Series provides precision measurement for sub-metering,\u003cbr\u003econtrols and energy management without dismantling\u003cbr\u003ethe main line. Ergonomically designed with secured latch and\u003cbr\u003ekeying hole for locking or servicing tag.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.3” x 1.7” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5\u003cbr\u003e• Approximate weight 1.1Lbs\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Byram Labs","offers":[{"title":"Default Title","offer_id":16660020625466,"sku":"1C1391","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/bl_4_8fa5ca16-2555-4e12-a413-c5c51533d343.png?v=1533131864"},{"product_id":"bl4-400-5-ct","title":"400:5 Split-Core Current Transformer | BL-4-400-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-4-400-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1B7028\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 400A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-4 Series provides precision measurement for sub-metering,\u003cbr\u003econtrols and energy management without dismantling\u003cbr\u003ethe main line. Ergonomically designed with secured latch and\u003cbr\u003ekeying hole for locking or servicing tag.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.3” x 1.7” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5\u003cbr\u003e• Approximate weight 1.1Lbs\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Byram Labs","offers":[{"title":"Default Title","offer_id":16660091600954,"sku":"1B7028","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/bl_4_9decd71e-76b3-4342-8362-e60a315801c6.png?v=1533131883"},{"product_id":"bl5-200-5-ct","title":"200:5 Split-Core Current Transformer | BL-5-200-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-5-200-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C2269\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 200A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-5 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 3.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 200 - 1000A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 1.7Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Byram Labs","offers":[{"title":"Default Title","offer_id":16660418920506,"sku":"1C2269","price":202.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/bl5.PNG?v=1532370900"},{"product_id":"bl5-400-5-ct","title":"400:5 Split-Core Current Transformer | BL-5-400-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-5-400-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C2268\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 400A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-5 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 3.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 200 - 1000A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 1.7Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Byram Labs","offers":[{"title":"Default Title","offer_id":16660938620986,"sku":"1C2268","price":202.57,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/bl-5_3d4df067-ffdc-45d5-855d-ecbe92dd2284.png?v=1533132050"},{"product_id":"bl5-600-5-ct","title":"600:5 Split-Core Current Transformer | BL-5-600-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-5-600-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C1417\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 600A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-5 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 3.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 200 - 1000A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 1.7Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Byram Labs","offers":[{"title":"Default Title","offer_id":16661044199482,"sku":"1C1417","price":202.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/bl-5_84812a9b-8079-4cd9-a6d0-5831a3746c76.png?v=1533132091"},{"product_id":"bl5-800-5-ct","title":"800:5 Split-Core Current Transformer | BL-5-800-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-5-800-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e 1C1479\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 800A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-5 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 3.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 200 - 1000A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 1.7Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Byram Labs","offers":[{"title":"Default Title","offer_id":16661144502330,"sku":"1C1479","price":202.57,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0020\/5753\/5546\/products\/bl-5_76805a55-d2cd-48a4-88db-beef08b7e811.png?v=1533132165"}],"url":"https:\/\/shop.byramlabs.com\/collections\/current-transformers.oembed?page=17","provider":"Byram Labs","version":"1.0","type":"link"}